Pages

Monday, December 5, 2016

Storage - HP CLI commands by example

======================
Commands Index
======================
For some reason the I/O on a system was very time consuming.
When checking with HP CLI commands, it was evident that the CompactFlash Controller components are faulted, making writes to the disk to be without cache, and as a result very slow.

======================
General commands:
======================
lsscsi
iostat

======================
HP CLI commands:
======================
show system
show time
show vdisks
show disks
show events error last 100


======================
HP hpacucli commands:
======================
HPACUCLI stands for HP Array Configuration Utility CLI.
HPACUCLI Reference

======================
HP hpssacli commands:
======================
HOSSACLI Reference
======================


======================

Examples
======================


root@db_server:~>% lsscsi
[1:0:9:0]    enclosu HP       P2000 G3 SAS     T250  -      
[1:0:9:10]   disk    HP       P2000 G3 SAS     T250  /dev/sdai
[1:0:9:11]   disk    HP       P2000 G3 SAS     T250  /dev/sdaj
[1:0:9:12]   disk    HP       P2000 G3 SAS     T250  /dev/sdak
[1:0:9:13]   disk    HP       P2000 G3 SAS     T250  /dev/sdal
[1:0:9:14]   disk    HP       P2000 G3 SAS     T250  /dev/sdam
[1:0:9:15]   disk    HP       P2000 G3 SAS     T250  /dev/sdan
[1:0:9:16]   disk    HP       P2000 G3 SAS     T250  /dev/sdao
[1:0:9:17]   disk    HP       P2000 G3 SAS     T250  /dev/sdap
[1:0:9:18]   disk    HP       P2000 G3 SAS     T250  /dev/sdaq
[1:0:9:19]   disk    HP       P2000 G3 SAS     T250  /dev/sdar
[1:0:9:20]   disk    HP       P2000 G3 SAS     T250  /dev/sdas
[1:0:9:21]   disk    HP       P2000 G3 SAS     T250  /dev/sdat
[1:0:9:22]   disk    HP       P2000 G3 SAS     T250  /dev/sdau
[1:0:9:23]   disk    HP       P2000 G3 SAS     T250  /dev/sdav
[1:0:9:24]   disk    HP       P2000 G3 SAS     T250  /dev/sdaw
[1:0:9:25]   disk    HP       P2000 G3 SAS     T250  /dev/sdax
[1:0:9:26]   disk    HP       P2000 G3 SAS     T250  /dev/sday
[1:0:9:27]   disk    HP       P2000 G3 SAS     T250  /dev/sdaz
[1:0:9:28]   disk    HP       P2000 G3 SAS     T250  /dev/sdba
[1:0:9:29]   disk    HP       P2000 G3 SAS     T250  /dev/sdbb
[1:0:9:30]   disk    HP       P2000 G3 SAS     T250  /dev/sdbc
[1:0:9:31]   disk    HP       P2000 G3 SAS     T250  /dev/sdbd
[1:0:9:32]   disk    HP       P2000 G3 SAS     T250  /dev/sdbe
[1:0:9:33]   disk    HP       P2000 G3 SAS     T250  /dev/sdbf
[1:0:9:34]   disk    HP       P2000 G3 SAS     T250  /dev/sdbg
[1:0:9:35]   disk    HP       P2000 G3 SAS     T250  /dev/sdbh
[1:0:9:36]   disk    HP       P2000 G3 SAS     T250  /dev/sdbi
[1:0:9:37]   disk    HP       P2000 G3 SAS     T250  /dev/sdbj
[1:0:9:38]   disk    HP       P2000 G3 SAS     T250  /dev/sdbk
[1:0:9:39]   disk    HP       P2000 G3 SAS     T250  /dev/sdbl
[1:0:9:40]   disk    HP       P2000 G3 SAS     T250  /dev/sdbm
[1:0:9:41]   disk    HP       P2000 G3 SAS     T250  /dev/sdbn
[1:0:9:50]   disk    HP       P2000 G3 SAS     T250  /dev/sdbo
[1:0:9:52]   disk    HP       P2000 G3 SAS     T250  /dev/sdbp
[1:0:9:60]   disk    HP       P2000 G3 SAS     T250  /dev/sdbq
[1:0:9:61]   disk    HP       P2000 G3 SAS     T250  /dev/sdbr


root@db_server:~>% iostat
Linux 2.6.18-308.24.1.el5 (db_server)     12/05/2016

avg-cpu:  %user   %nice %system %iowait  %steal   %idle
           9.25    0.00    2.78    1.55    0.00   86.42

Device:            tps   Blk_read/s   Blk_wrtn/s   Blk_read   Blk_wrtn
cciss/c0d0       19.91       195.40       834.04 17116726059 73061406312
cciss/c0d0p1      0.01         0.00         0.00          0          0
cciss/c0d0p2     19.90         0.00         0.00          0          0
dm-0              0.00         0.00         0.00      49482      62136
dm-1              9.74        10.83        76.65  948509642 6714683808
dm-2              6.29         9.77        47.07  855453178 4123664168
dm-3             68.96         3.28       549.89  287077202 48170202184
dm-4              1.46         2.97        11.48  260490314 1005519912
dm-5              4.15         2.46        32.72  215611762 2866339352
dm-6              0.01         0.02         0.05    1578930    4773624
dm-7              0.02         0.07         0.11    6364480    9672624
dm-8              1.81        16.14        11.27 1413684858  986900392
dm-9              0.00         0.00         0.00       1832          0
dm-10             0.00         0.00         0.00       1832          0
dm-11             0.02         1.83         0.04  160358298    3839128
dm-12            15.41       144.36       104.45 12646223930 9149346952
dm-13             0.12         2.94         0.30  257146754   26323944
dm-14             0.00         0.00         0.00      47534      31910
dm-15             0.00         0.00         0.00       1832          0
dm-16             0.00         0.00         0.00       1832          0
dm-17             0.00         0.00         0.00        880          0
dm-18             0.00         0.00         0.00        880          0
dm-19             0.00         0.00         0.00        880          0
dm-20             0.00         0.00         0.00        920          0
dm-21             0.00         0.00         0.00        920          0
dm-22             0.00         0.00         0.00        920          0
dm-23             0.00         0.00         0.00        920          0
dm-24             0.00         0.00         0.00        920          0




cd /usr/local/etc/starhome/load_alarm/conf/
root@db_server:/usr/local/etc/starhome/load_alarm/conf>% cat load_alarm.conf
cpu_critical=90
cpu_warning=85
memory_critical=95
memory_warning=90
disk_critical=90
disk_warning=85
check_msa=1
msa_ip1=111.222.333.216
msa_ip2=111.222.333.217

root@db_server:/usr/local/etc/starhome/load_alarm/conf>% ssh 111.222.333.217
Password:
HP StorageWorks MSA Storage P2000 G3 SAS
System Name: my_system
System Location: MY_COMPANY
Version: TS250P002
# show system
System Information
------------------
System Name: my_system
System Contact: MY_COMPANY
System Location: MY_COMPANY
System Information: MY_COMPANY
Midplane Serial Number: 00557PO19E22A
Vendor Name: HP StorageWorks
Product ID: P2000 G3 SAS
Product Brand: MSA Storage
SCSI Vendor ID: HP
SCSI Product ID: P2000 G3 SAS
Enclosure Count: 1
Health: Degraded
Health Reason: A subcomponent of this component is unhealthy.
Supported Locales: English (English), Spanish (español), French (français), German (Deutsch), Italian (italiano), Japanese (æ¥æ¬èª), Dutch (Nederlands), Chinese-Simplified (ç®ä½ä¸­æ), Chinese-Traditional (ç¹é«ä¸­æ), Korean (íêµ­ì´)

  Unhealthy Component
  -------------------
  Component ID: Enclosure 1, Controller A, CompactFlash
  Health: Fault
  Health Reason: The component is not present.
  Health Recommendation: - Replace the FRU that contains this component.

  Unhealthy Component
  -------------------
  Component ID: Enclosure 1, Controller B, CompactFlash
  Health: Fault
  Health Reason: The component is not present.
  Health Recommendation: - Replace the FRU that contains this component.

  Unhealthy Component
  -------------------               
  Component ID: Disk 1.7
  Health: Degraded
  Health Reason: The disk may contain invalid metadata.
  Health Recommendation: - See "Troubleshooting Steps for Leftover Drives" in the HP MSA2000/P2000 Guided Troubleshooting Best Practices.


Success: Command completed successfully. (2016-12-05 13:04:00)


# show vdisks
Name    Size     Free     Own Pref   RAID   Disks Spr Chk  Status Jobs      Job%      Serial Number                    Drive Spin Down       
  Spin Down Delay       Health     Health Reason Health Recommendation
----------------------------------------------------------------------------------------------------------------------------------------------
vdisk1  4796.0GB 3536.0GB A   A      RAID10 16    0   64k  FTOL                       00c0ff19c45a0000e33c235200000000 Disabled              
  0                     OK                                            
vdisk2  1199.0GB 68.9GB   B   B      RAID10 4     0   64k  FTOL                       00c0ff19c4590000eb3c235200000000 Disabled              
  0                     OK                                            
vdisk3  599.5GB  59.4GB   A   A      RAID1  2     0   N/A  FTOL                       00c0ff19c45a0000ef3c235200000000 Disabled              
  0                     OK                                             
----------------------------------------------------------------------------------------------------------------------------------------------
Success: Command completed successfully. (2016-12-05 13:06:49)

# show disks
Location Serial Number         Vendor   Rev              How Used   Type Size    Rate*(Gb/s) SP Health    
  Health Reason                          
  Health Recommendation                                                                                             
--------------------------------------------------------------------------------------------------------------------
1.1      EA01PD51VTA01320      HP       HPD6             VDISK      SAS  600.1GB 3.0            OK        
                                          
  
1.2      EA01PD51VT1A1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.3      EA01PD51VSKW1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.4      EA01PD51VPG01320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.5      EA01PD51VPPV1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.6      EA01PD51VT0K1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.7      EA01PD51VSPC1320      HP       HPD6             LEFTOVR    SAS  600.1GB 6.0            Degraded  
  The disk may contain invalid metadata. 
  - See "Troubleshooting Steps for Leftover Drives" in the HP MSA2000/P2000 Guided Troubleshooting Best Practices.
1.8      EA01PD51VPPW1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.9      EA01PD51VT1W1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.10     EA01PD51VTEG1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
                                     
1.11     EA01PD51VSMG1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.12     EA01PD51VTDL1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.13     EA01PD51VT0U1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK         
                                          
  
1.14     EA01PD51VPGK1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.15     EA01PD51W1B21321      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
1.16     EA01PD51VSM01320      HP       HPD6             VDISK      SAS  600.1GB 3.0            OK        
                                          
  
1.17     EA01PD51W19G1321      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.18     EA01PD51W0M71321      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK         
                                          
  
1.19     EA01PD51W0M11321      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.20     EA01PD51W14F1321      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.21     EA01PD51VPRA1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
                                     
1.22     EA01PD51VTDT1320      HP       HPD6             VDISK      SAS  600.1GB 6.0            OK        
                                          
  
1.23     EA01PD51W1211321      HP       HPD6             VDISK      SAS  600.1GB 3.0            OK        
                                          
  
1.24     EA01PD51W16U1321      HP       HPD6             AVAIL      SAS  600.1GB 6.0            OK        
                                          
  
--------------------------------------------------------------------------------------------------------------------
Info: * Rates may vary. This is normal behavior. (2016-12-05 13:06:55)

Success: Command completed successfully. (2016-12-05 13:06:55)

# show events error last 100
2016-12-05 11:18:28 [354] #B9887: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-05 11:18:27 [354] #A11028: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 15:25:52 [354] #B9881: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 15:25:51 [354] #A11022: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 12:01:54 [354] #A11015: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 12:01:54 [354] #A11014: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 12:01:06 [204] #A10990: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING An error was detected related to the CompactFlash card.  
2016-12-04 12:01:06 [242] #A10989: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A ERROR Auto-write-through trigger event: CompactFlash failed.  
2016-12-04 12:00:19 [112] #A10985: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)  
2016-12-04 12:00:19 [112] #A10984: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)  
2016-12-04 12:00:19 [112] #A10983: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)  
2016-12-04 12:00:19 [112] #A10982: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)  
2016-12-04 11:36:48 [354] #A10975: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 11:36:48 [354] #A10974: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 11:36:48 [354] #B9852: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 11:36:48 [354] #B9851: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 11:36:00 [204] #A10951: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING An error was detected related to the CompactFlash card.  
2016-12-04 11:36:00 [242] #A10950: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A ERROR Auto-write-through trigger event: CompactFlash failed.  
2016-12-04 11:35:13 [112] #A10946: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)  
2016-12-04 11:35:13 [112] #A10945: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)  
2016-12-04 11:35:13 [112] #A10944: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)  
2016-12-04 11:35:13 [112] #A10943: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)  
2016-12-04 11:28:13 [354] #B9828: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 11:28:13 [354] #B9827: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-12-04 11:27:26 [204] #A10912: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING An error was detected related to the CompactFlash card.  
2016-12-04 11:27:26 [242] #A10911: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A ERROR Auto-write-through trigger event: CompactFlash failed.  
2016-12-04 11:26:39 [112] #A10907: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)  
2016-12-04 11:26:39 [112] #A10906: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)  
2016-12-04 11:26:39 [112] #A10905: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)  
2016-12-04 11:26:39 [112] #A10904: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)  
2016-01-21 23:37:54 [495] #A9771: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING The algorithm for best-path routing selected the alterna
te path to a disk because the I/O error count on the primary path reached its threshold. (disk: channel: 0, ID: 22, SN: EA01PD51W1211321, enclosure: 1, slot: 23)  
2016-01-21 23:37:16 [204] #B9071: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING An error was detected related to the CompactFlash card.  
2016-01-21 23:37:16 [242] #B9070: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event: CompactFlash failed.  
2016-01-21 23:33:31 [354] #A9753: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-01-21 23:33:31 [354] #A9752: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-01-21 23:31:55 [084] #A9741: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Killed partner controller. (reason: Other not present)  
2016-01-21 23:25:51 [354] #A9732: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-01-21 23:25:51 [354] #A9731: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2016-01-21 23:25:49 [204] #B9043: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING An error was detected related to the CompactFlash card.  
2016-01-21 23:25:49 [242] #B9042: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event: CompactFlash failed.  
2016-01-21 23:24:15 [084] #A9715: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Killed partner controller. (reason: Other not present)  
2016-01-21 23:20:55 [495] #A9694: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING The algorithm for best-path routing selected the alternate path to a disk because the I/O error count on the primary path reached its threshold. (disk: channel: 0, ID: 22, SN: EA01PD51W1211321, enclosure: 1, slot: 23)  
2016-01-21 23:20:21 [204] #B9017: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING An error was detected related to the CompactFlash card.  
2016-01-21 23:20:21 [242] #B9016: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event: CompactFlash failed.  
2016-01-21 23:16:15 [314] #A9681: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A ERROR There is a problem with a FRU. (FRU type: A/C PSU, Right, enclosure: 1, product ID: , SN: , version: , related event serial number: A9680, related event code: 168)  
2016-01-21 23:16:15 [168] #A9680: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A ERROR Enclosure event: fault. (enclosure: 1, WWN: 500c0ff019e22a3c) power supply 2, power supply status:  DC failure, AC failure, HP      SPS-CHASSIS     2023  
2016-01-20 22:27:17 [274] #B9006: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING A PHY was disabled. (enclosure: 1, module (disabled path
to this disk): B, disk slot: 7, reason: Disabled because of empty disk slot)  
2016-01-20 22:27:17 [274] #B9005: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING A PHY was disabled. (enclosure: 1, module (disabled path to this disk): A, disk slot: 7, reason: Disabled because of empty disk slot)  
2016-01-20 22:27:12 [274] #A9665: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING A PHY was disabled. (enclosure: 1, module (disabled path to this disk): B, disk slot: 7, reason: Disabled because of empty disk slot)  
2016-01-20 22:27:12 [274] #A9664: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING A PHY was disabled. (enclosure: 1, module (disabled path to this disk): A, disk slot: 7, reason: Disabled because of empty disk slot)  
2015-09-17 10:51:15 [354] #B8758: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2015-09-17 10:51:15 [354] #B8757: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2015-09-17 10:51:14 [354] #A9235: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2015-09-17 10:51:14 [354] #A9234: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2015-09-17 10:50:26 [204] #B8735: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING An error was detected related to the CompactFlash card.  
2015-09-17 10:50:26 [242] #B8734: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event: CompactFlash failed.  
2015-09-17 10:49:38 [112] #B8730: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 4)  
2015-09-17 10:49:38 [112] #B8729: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 3)  
2015-09-17 10:49:38 [112] #B8728: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 2)  
2015-09-17 10:49:38 [112] #B8727: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 1)  
2015-09-17 10:16:49 [354] #B8705: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2015-09-17 10:16:49 [354] #B8704: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2015-09-17 10:16:38 [112] #A9182: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)  
2015-09-17 10:16:38 [112] #A9181: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)  
2015-09-17 10:16:37 [112] #A9180: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)  
2015-09-17 10:16:37 [112] #A9179: P2000 G3 SAS Array SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)  
2015-09-17 10:16:01 [204] #B8670: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING An error was detected related to the CompactFlash card.  
2015-09-17 10:16:01 [242] #B8669: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event: CompactFlash failed.  
2015-09-17 10:15:14 [112] #B8665: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 4)  
2015-09-17 10:15:14 [112] #B8664: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 3)  
2015-09-17 10:15:14 [112] #B8663: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 2)  
2015-09-17 10:15:14 [112] #B8662: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 1)  
2014-07-01 21:44:01 [314] #B7734: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR There is a problem with a FRU. (FRU type: A/C PSU, Right, enclosure: 1, product ID: , SN: , version: , related event serial number: B7733, related event code: 168)  
2014-07-01 21:44:01 [168] #B7733: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Enclosure event: fault. (enclosure: 1, WWN: 500c0ff019e22a3c) power supply 2, power supply status:  AC failure, HP      SPS-CHASSIS     2023  
2014-07-01 21:39:51 [314] #B7729: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR There is a problem with a FRU. (FRU type: A/C PSU, Left, enclosure: 1, product ID: , SN: , version: , related event serial number: B7728, related event code: 168)  
2014-07-01 21:39:51 [168] #B7728: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B ERROR Enclosure event: fault. (enclosure: 1, WWN: 500c0ff019e22a3c) power supply 1, power supply status:  DC failure, AC failure, HP      SPS-CHASSIS     2023  

2014-05-22 05:56:43 [354] #B7649: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2014-02-25 16:02:03 [354] #B7482: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 1, 0 out of 4 PHYs are up, link speed: Autonegotiated)  
2014-02-25 15:58:35 [354] #B7481: P2000 G3 SAS Array SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port: 2, 0 out of 4 PHYs are up, link speed: Autonegotiated)  

Success: Command completed successfully. (2016-12-05 13:07:35)

#
# show time
Error: The command was not recognized. (2016-12-05 13:08:46)

======================
HP hpacucli commands:
======================
Basic general check:

root@my_server:~>% hpacucli ctrl slot=0 ld all show

Error: The controller identified by "slot=0" was not detected.

root@my_server:~>% hpacucli ctrl all show

Smart Array P400 in Slot 1    (sn: P61620F9VV69P4)

root@my_server:~>% hpacucli ctrl slot=1 ld all show

Smart Array P400 in Slot 1

   array A

      logicaldrive 1 (136.7 GB, RAID 1+0, OK)

   array B (Failed)

      logicaldrive 2 (136.7 GB, RAID 1+0, Failed)


   array C
      logicaldrive 3 (136.7 GB, RAID 1+0, OK)


======================
HP hpssacli commands:
======================
root@my_server:~>% hpssacli ctrl all show config



Smart Array P440ar in Slot 0 (Embedded)   (sn: PDNLH0BRH1726V)



   Internal Drive Cage at Port 1I, Box 3, OK

   Internal Drive Cage at Port 2I, Box 0, OK
   array A (SAS, Unused Space: 0  MB)

      logicaldrive 1 (558.9 GB, RAID 1, OK)

      physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS, 600 GB, OK)
      physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS, 600 GB, OK)



root@my_server:~>% hpssacli ctrl all show status

Smart Array P440ar in Slot 0 (Embedded)
   Controller Status: OK
   Cache Status: OK
   Battery/Capacitor Status: OK