======================
Commands Index
======================
For some reason the I/O on a system was very time consuming.
When checking with HP CLI commands, it was evident that the CompactFlash Controller components are faulted, making writes to the disk to be without cache, and as a result very slow.
======================
General commands:
======================
lsscsi
iostat
======================
HP CLI commands:
======================
show system
show time
show vdisks
show disks
show events error last 100
======================
HP hpacucli commands:
======================HPACUCLI stands for HP Array Configuration Utility CLI.
HPACUCLI Reference
======================
HP hpssacli commands:
======================
HOSSACLI Reference
======================
======================
Examples
======================
root@db_server:~>% lsscsi
[1:0:9:0] enclosu
HP P2000 G3 SAS
T250 -
[1:0:9:10] disk
HP P2000 G3 SAS
T250 /dev/sdai
[1:0:9:11] disk
HP P2000 G3 SAS
T250 /dev/sdaj
[1:0:9:12] disk
HP P2000 G3 SAS
T250 /dev/sdak
[1:0:9:13] disk
HP P2000 G3 SAS
T250 /dev/sdal
[1:0:9:14] disk
HP P2000 G3 SAS
T250 /dev/sdam
[1:0:9:15] disk
HP P2000 G3 SAS
T250 /dev/sdan
[1:0:9:16] disk
HP P2000 G3 SAS
T250 /dev/sdao
[1:0:9:17] disk
HP P2000 G3 SAS
T250 /dev/sdap
[1:0:9:18] disk
HP P2000 G3 SAS
T250 /dev/sdaq
[1:0:9:19] disk
HP P2000 G3 SAS
T250 /dev/sdar
[1:0:9:20] disk
HP P2000 G3 SAS
T250 /dev/sdas
[1:0:9:21] disk
HP P2000 G3 SAS
T250 /dev/sdat
[1:0:9:22] disk
HP P2000 G3 SAS
T250 /dev/sdau
[1:0:9:23] disk
HP P2000 G3 SAS
T250 /dev/sdav
[1:0:9:24] disk
HP P2000 G3 SAS
T250 /dev/sdaw
[1:0:9:25] disk
HP P2000 G3 SAS
T250 /dev/sdax
[1:0:9:26] disk
HP P2000 G3 SAS
T250 /dev/sday
[1:0:9:27] disk
HP P2000 G3 SAS
T250 /dev/sdaz
[1:0:9:28] disk
HP P2000 G3 SAS
T250 /dev/sdba
[1:0:9:29] disk
HP P2000 G3 SAS
T250 /dev/sdbb
[1:0:9:30] disk
HP P2000 G3 SAS
T250 /dev/sdbc
[1:0:9:31] disk
HP P2000 G3 SAS
T250 /dev/sdbd
[1:0:9:32] disk
HP P2000 G3
SAS T250 /dev/sdbe
[1:0:9:33] disk
HP P2000 G3 SAS
T250 /dev/sdbf
[1:0:9:34] disk HP
P2000 G3 SAS T250 /dev/sdbg
[1:0:9:35] disk
HP P2000 G3 SAS
T250 /dev/sdbh
[1:0:9:36] disk
HP P2000 G3 SAS
T250 /dev/sdbi
[1:0:9:37] disk
HP P2000 G3 SAS
T250 /dev/sdbj
[1:0:9:38] disk
HP P2000 G3 SAS
T250 /dev/sdbk
[1:0:9:39] disk
HP P2000 G3 SAS
T250 /dev/sdbl
[1:0:9:40] disk
HP P2000 G3 SAS
T250 /dev/sdbm
[1:0:9:41] disk
HP P2000 G3 SAS
T250 /dev/sdbn
[1:0:9:50] disk
HP P2000 G3 SAS
T250 /dev/sdbo
[1:0:9:52] disk
HP P2000 G3 SAS
T250 /dev/sdbp
[1:0:9:60] disk
HP P2000 G3 SAS
T250 /dev/sdbq
[1:0:9:61] disk
HP P2000 G3 SAS
T250 /dev/sdbr
root@db_server:~>% iostat
Linux 2.6.18-308.24.1.el5
(db_server) 12/05/2016
avg-cpu: %user %nice %system %iowait
%steal %idle
9.25 0.00 2.78
1.55 0.00 86.42
Device:
tps Blk_read/s Blk_wrtn/s Blk_read
Blk_wrtn
cciss/c0d0
19.91
195.40 834.04 17116726059 73061406312
cciss/c0d0p1
0.01
0.00
0.00
0 0
cciss/c0d0p2
19.90
0.00
0.00
0 0
dm-0
0.00
0.00
0.00 49482 62136
dm-1
9.74
10.83 76.65 948509642
6714683808
dm-2
6.29
9.77 47.07 855453178 4123664168
dm-3
68.96
3.28 549.89 287077202 48170202184
dm-4
1.46
2.97 11.48 260490314 1005519912
dm-5
4.15
2.46 32.72 215611762 2866339352
dm-6
0.01
0.02 0.05
1578930 4773624
dm-7
0.02 0.07
0.11 6364480 9672624
dm-8
1.81
16.14 11.27 1413684858
986900392
dm-9
0.00
0.00
0.00 1832
0
dm-10
0.00
0.00
0.00 1832
0
dm-11
0.02
1.83 0.04
160358298 3839128
dm-12
15.41
144.36 104.45 12646223930 9149346952
dm-13
0.12
2.94 0.30
257146754 26323944
dm-14
0.00
0.00
0.00 47534 31910
dm-15
0.00
0.00
0.00 1832
0
dm-16
0.00
0.00
0.00 1832
0
dm-17
0.00
0.00
0.00 880
0
dm-18
0.00
0.00
0.00
880 0
dm-19
0.00
0.00
0.00 880
0
dm-20
0.00
0.00
0.00 920
0
dm-21
0.00
0.00
0.00 920
0
dm-22
0.00
0.00
0.00 920
0
dm-23
0.00
0.00
0.00 920
0
dm-24
0.00
0.00
0.00 920
0
cd /usr/local/etc/starhome/load_alarm/conf/
root@db_server:/usr/local/etc/starhome/load_alarm/conf>%
cat load_alarm.conf
cpu_critical=90
cpu_warning=85
memory_critical=95
memory_warning=90
disk_critical=90
disk_warning=85
check_msa=1
msa_ip1=111.222.333.216
msa_ip2=111.222.333.217
root@db_server:/usr/local/etc/starhome/load_alarm/conf>%
ssh 111.222.333.217
Password:
HP StorageWorks MSA Storage P2000 G3 SAS
System Name: my_system
System Location: MY_COMPANY
Version: TS250P002
# show system
System Information
------------------
System Name: my_system
System Contact: MY_COMPANY
System Location: MY_COMPANY
System Information: MY_COMPANY
Midplane Serial Number: 00557PO19E22A
Vendor Name: HP StorageWorks
Product ID: P2000 G3 SAS
Product Brand: MSA Storage
SCSI Vendor ID: HP
SCSI Product ID: P2000 G3 SAS
Enclosure Count: 1
Health: Degraded
Health Reason: A subcomponent of this component is
unhealthy.
Supported Locales: English (English), Spanish (español),
French (français), German (Deutsch), Italian (italiano), Japanese (æ¥æ¬èª),
Dutch (Nederlands), Chinese-Simplified (ç®ä½ä¸æ), Chinese-Traditional (ç¹é«ä¸æ),
Korean (íêµì´)
Unhealthy Component
-------------------
Component ID: Enclosure 1, Controller A, CompactFlash
Health: Fault
Health Reason: The component is not present.
Health Recommendation: - Replace the FRU that contains this
component.
Unhealthy Component
-------------------
Component ID: Enclosure 1, Controller B, CompactFlash
Health: Fault
Health Reason: The component is not present.
Health Recommendation: - Replace the FRU that contains this
component.
Unhealthy Component
-------------------
Component ID: Disk 1.7
Health: Degraded
Health Reason: The disk may contain invalid metadata.
Health Recommendation: - See "Troubleshooting
Steps for Leftover Drives" in the HP MSA2000/P2000 Guided Troubleshooting
Best Practices.
Success: Command completed successfully. (2016-12-05
13:04:00)
# show vdisks
Name Size
Free Own Pref RAID Disks Spr
Chk Status Jobs
Job% Serial Number
Drive Spin Down
Spin Down
Delay Health Health
Reason Health Recommendation
----------------------------------------------------------------------------------------------------------------------------------------------
vdisk1 4796.0GB 3536.0GB A
A RAID10 16 0
64k
FTOL
00c0ff19c45a0000e33c235200000000 Disabled
0
OK
vdisk2 1199.0GB 68.9GB B
B RAID10 4 0
64k
FTOL
00c0ff19c4590000eb3c235200000000
Disabled
0
OK
vdisk3 599.5GB 59.4GB A
A RAID1 2
0 N/A
FTOL
00c0ff19c45a0000ef3c235200000000 Disabled
0
OK
----------------------------------------------------------------------------------------------------------------------------------------------
Success: Command completed successfully. (2016-12-05
13:06:49)
# show disks
Location Serial
Number Vendor
Rev
How Used Type Size Rate*(Gb/s) SP
Health
Health
Reason
Health
Recommendation
--------------------------------------------------------------------------------------------------------------------
1.1
EA01PD51VTA01320
HP
HPD6
VDISK SAS 600.1GB
3.0
OK
1.2
EA01PD51VT1A1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.3 EA01PD51VSKW1320
HP
HPD6
VDISK SAS 600.1GB
6.0
OK
1.4
EA01PD51VPG01320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.5
EA01PD51VPPV1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.6
EA01PD51VT0K1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.7
EA01PD51VSPC1320
HP
HPD6
LEFTOVR SAS 600.1GB 6.0
Degraded
The disk may contain invalid metadata.
- See "Troubleshooting Steps for Leftover
Drives" in the HP MSA2000/P2000 Guided Troubleshooting Best Practices.
1.8
EA01PD51VPPW1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.9
EA01PD51VT1W1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.10
EA01PD51VTEG1320
HP HPD6
VDISK SAS 600.1GB
6.0
OK
1.11
EA01PD51VSMG1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.12
EA01PD51VTDL1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.13
EA01PD51VT0U1320
HP
HPD6
VDISK SAS 600.1GB
6.0
OK
1.14
EA01PD51VPGK1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.15
EA01PD51W1B21321
HP
HPD6
VDISK SAS
600.1GB 6.0
OK
1.16
EA01PD51VSM01320
HP
HPD6
VDISK SAS 600.1GB 3.0
OK
1.17
EA01PD51W19G1321
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.18
EA01PD51W0M71321
HP
HPD6
VDISK SAS 600.1GB
6.0
OK
1.19
EA01PD51W0M11321
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.20
EA01PD51W14F1321
HP HPD6
VDISK
SAS 600.1GB 6.0
OK
1.21
EA01PD51VPRA1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.22
EA01PD51VTDT1320
HP
HPD6
VDISK SAS 600.1GB 6.0
OK
1.23 EA01PD51W1211321
HP
HPD6
VDISK SAS 600.1GB
3.0
OK
1.24
EA01PD51W16U1321
HP
HPD6
AVAIL SAS 600.1GB 6.0
OK
--------------------------------------------------------------------------------------------------------------------
Info: * Rates may vary. This is normal behavior. (2016-12-05
13:06:55)
Success: Command completed successfully. (2016-12-05
13:06:55)
# show events error last 100
2016-12-05 11:18:28 [354] #B9887: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-05 11:18:27 [354] #A11028: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 15:25:52 [354] #B9881: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 15:25:51 [354] #A11022: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 12:01:54 [354] #A11015: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 12:01:54 [354] #A11014: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 12:01:06 [204] #A10990: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING An error was detected related to the
CompactFlash card.
2016-12-04 12:01:06 [242] #A10989: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A ERROR Auto-write-through trigger event:
CompactFlash failed.
2016-12-04 12:00:19 [112] #A10985: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)
2016-12-04 12:00:19 [112] #A10984: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)
2016-12-04 12:00:19 [112] #A10983: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)
2016-12-04 12:00:19 [112] #A10982: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)
2016-12-04 11:36:48 [354] #A10975: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 11:36:48 [354] #A10974: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 11:36:48 [354] #B9852: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 11:36:48 [354] #B9851: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 11:36:00 [204] #A10951: P2000 G3 SAS Array SN#00C0FF19FA59
Controller A WARNING An error was detected related to the CompactFlash
card.
2016-12-04 11:36:00 [242] #A10950: P2000 G3 SAS Array SN#00C0FF19FA59
Controller A ERROR Auto-write-through trigger event: CompactFlash failed.
2016-12-04 11:35:13 [112] #A10946: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)
2016-12-04 11:35:13 [112] #A10945: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)
2016-12-04 11:35:13 [112] #A10944: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)
2016-12-04 11:35:13 [112] #A10943: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)
2016-12-04 11:28:13 [354] #B9828: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 11:28:13 [354] #B9827: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-12-04 11:27:26 [204] #A10912: P2000 G3 SAS Array SN#00C0FF19FA59
Controller A WARNING An error was detected related to the CompactFlash
card.
2016-12-04 11:27:26 [242] #A10911: P2000 G3 SAS Array SN#00C0FF19FA59
Controller A ERROR Auto-write-through trigger event: CompactFlash failed.
2016-12-04 11:26:39 [112] #A10907: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)
2016-12-04 11:26:39 [112] #A10906: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)
2016-12-04 11:26:39 [112] #A10905: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)
2016-12-04 11:26:39 [112] #A10904: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)
2016-01-21 23:37:54 [495] #A9771: P2000 G3 SAS Array SN#00C0FF19FA59
Controller A WARNING The algorithm for best-path routing selected the alterna
te path to a disk because the I/O error count on the primary
path reached its threshold. (disk: channel: 0, ID: 22, SN: EA01PD51W1211321,
enclosure: 1, slot: 23)
2016-01-21 23:37:16 [204] #B9071: P2000 G3 SAS Array SN#00C0FF19FA59
Controller B WARNING An error was detected related to the CompactFlash card.
2016-01-21 23:37:16 [242] #B9070: P2000 G3 SAS Array SN#00C0FF19FA59
Controller B ERROR Auto-write-through trigger event: CompactFlash failed.
2016-01-21 23:33:31 [354] #A9753: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-01-21 23:33:31 [354] #A9752: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-01-21 23:31:55 [084] #A9741: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Killed partner controller. (reason: Other
not present)
2016-01-21 23:25:51 [354] #A9732: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-01-21 23:25:51 [354] #A9731: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2016-01-21 23:25:49 [204] #B9043: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING An error was detected related to the
CompactFlash card.
2016-01-21 23:25:49 [242] #B9042: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event:
CompactFlash failed.
2016-01-21 23:24:15 [084] #A9715: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Killed partner controller. (reason: Other
not present)
2016-01-21 23:20:55 [495] #A9694: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING The algorithm for best-path routing
selected the alternate path to a disk because the I/O error count on the
primary path reached its threshold. (disk: channel: 0, ID: 22, SN:
EA01PD51W1211321, enclosure: 1, slot: 23)
2016-01-21 23:20:21 [204] #B9017: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING An error was detected related to the
CompactFlash card.
2016-01-21 23:20:21 [242] #B9016: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event:
CompactFlash failed.
2016-01-21 23:16:15 [314] #A9681: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A ERROR There is a problem with a FRU. (FRU type:
A/C PSU, Right, enclosure: 1, product ID: , SN: , version: , related event
serial number: A9680, related event code: 168)
2016-01-21 23:16:15 [168] #A9680: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A ERROR Enclosure event: fault. (enclosure: 1, WWN:
500c0ff019e22a3c) power supply 2, power supply status: DC failure, AC
failure, HP SPS-CHASSIS
2023
2016-01-20 22:27:17 [274] #B9006: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING A PHY was disabled. (enclosure: 1, module
(disabled path
to this disk): B, disk slot: 7, reason: Disabled because of
empty disk slot)
2016-01-20 22:27:17 [274] #B9005: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING A PHY was disabled. (enclosure: 1, module
(disabled path to this disk): A, disk slot: 7, reason: Disabled because of
empty disk slot)
2016-01-20 22:27:12 [274] #A9665: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING A PHY was disabled. (enclosure: 1, module
(disabled path to this disk): B, disk slot: 7, reason: Disabled because of
empty disk slot)
2016-01-20 22:27:12 [274] #A9664: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING A PHY was disabled. (enclosure: 1, module
(disabled path to this disk): A, disk slot: 7, reason: Disabled because of
empty disk slot)
2015-09-17 10:51:15 [354] #B8758: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2015-09-17 10:51:15 [354] #B8757: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2015-09-17 10:51:14 [354] #A9235: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2015-09-17 10:51:14 [354] #A9234: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2015-09-17 10:50:26 [204] #B8735: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING An error was detected related to the
CompactFlash card.
2015-09-17 10:50:26 [242] #B8734: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event:
CompactFlash failed.
2015-09-17 10:49:38 [112] #B8730: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 4)
2015-09-17 10:49:38 [112] #B8729: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 3)
2015-09-17 10:49:38 [112] #B8728: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 2)
2015-09-17 10:49:38 [112] #B8727: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 1)
2015-09-17 10:16:49 [354] #B8705: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2015-09-17 10:16:49 [354] #B8704: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2015-09-17 10:16:38 [112] #A9182: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 4)
2015-09-17 10:16:38 [112] #A9181: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 3)
2015-09-17 10:16:37 [112] #A9180: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 2)
2015-09-17 10:16:37 [112] #A9179: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller A WARNING Host link down. (port: 1)
2015-09-17 10:16:01 [204] #B8670: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING An error was detected related to the
CompactFlash card.
2015-09-17 10:16:01 [242] #B8669: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR Auto-write-through trigger event:
CompactFlash failed.
2015-09-17 10:15:14 [112] #B8665: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 4)
2015-09-17 10:15:14 [112] #B8664: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 3)
2015-09-17 10:15:14 [112] #B8663: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 2)
2015-09-17 10:15:14 [112] #B8662: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host link down. (port: 1)
2014-07-01 21:44:01 [314] #B7734: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR There is a problem with a FRU. (FRU type:
A/C PSU, Right, enclosure: 1, product ID: , SN: , version: , related event
serial number: B7733, related event code: 168)
2014-07-01 21:44:01 [168] #B7733: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR Enclosure event: fault. (enclosure: 1, WWN:
500c0ff019e22a3c) power supply 2, power supply status: AC failure,
HP SPS-CHASSIS
2023
2014-07-01 21:39:51 [314] #B7729: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR There is a problem with a FRU. (FRU type:
A/C PSU, Left, enclosure: 1, product ID: , SN: , version: , related event
serial number: B7728, related event code: 168)
2014-07-01 21:39:51 [168] #B7728: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B ERROR Enclosure event: fault. (enclosure: 1, WWN:
500c0ff019e22a3c) power supply 1, power supply status: DC failure, AC
failure, HP SPS-CHASSIS
2023
2014-05-22 05:56:43 [354] #B7649: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2014-02-25 16:02:03 [354] #B7482: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
1, 0 out of 4 PHYs are up, link speed: Autonegotiated)
2014-02-25 15:58:35 [354] #B7481: P2000 G3 SAS Array
SN#00C0FF19FA59 Controller B WARNING Host SAS topology was changed. (host port:
2, 0 out of 4 PHYs are up, link speed: Autonegotiated)
Success: Command completed successfully. (2016-12-05
13:07:35)
#
# show time
Error: The command was not recognized. (2016-12-05 13:08:46)
======================
HP hpacucli commands:
======================Basic general check:
root@my_server:~>% hpacucli ctrl slot=0 ld all show
Error: The controller identified by "slot=0" was not detected.
root@my_server:~>% hpacucli ctrl all show
Smart Array P400 in Slot 1 (sn: P61620F9VV69P4)
root@my_server:~>% hpacucli ctrl slot=1 ld all show
Smart Array P400 in Slot 1
array A
logicaldrive 1 (136.7 GB, RAID 1+0, OK)
array B (Failed)
logicaldrive 2 (136.7 GB, RAID 1+0, Failed)
array C
logicaldrive 3 (136.7 GB, RAID 1+0, OK)
======================
HP hpssacli commands:
======================
root@my_server:~>% hpssacli ctrl all show config
Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH1726V)
Internal Drive Cage at Port 1I, Box 3, OK
Internal Drive Cage at Port 2I, Box 0, OK
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (558.9 GB, RAID 1, OK)
physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS, 600 GB, OK)
root@my_server:~>% hpssacli ctrl all show status
Smart Array P440ar in Slot 0 (Embedded)
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
Smart Array P440ar in Slot 0 (Embedded)
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
No comments:
Post a Comment